한영넉스

Solid State Relay > HSR-SL series : HANYOUNG NUX
HSR-SL series Slim-type single-phase Solid State Relay
- 22.4mm slim type
- Optimal heat dissipation design, semi-permanent lifespan
- Selectable integrated/separate heat sink
- Bolt, DIN Rail attachment method
- High insulation between input/output

The order from the left is the order in which the information is displayed at the bottom. If you cancel the check, the information will be excluded, and if you check, it will be printed out.

print_icon

▍Specification

■ DC input

Model

Low

HSR-SLD15LR□□

HSR-SLD25LR□□

HSR-SLD40LR□□

HSR-SLD15LZ□□

HSR-SLD25LZ□□

HSR-SLD40LZ□□

High

HSR-SLD15HR□□

HSR-SLD25HR□□

HSR-SLD40HR□□

HSR-SLD15HZ□□

HSR-SLD25HZ□□

HSR-SLD40HZ□□

Certification

CE RU ROHS2

Weight Integrated

heat sink (with box)

CE, UL

Approx. 226g

Approx. 266g

■ S-MARK certified products (DC input)

Model

Low

HSR-SLD15LZ□-S

HSR-SLD25LZ□-S

HSR-SLD40LZ□-S

High

HSR-SLD15HZ□-S

HSR-SLD25HZ□-S

HSR-SLD40HZ□-S

certification

CE RU ROHS2 S

Weight Integrated

heat sink (with box)

S-MARK

Approx. 226g

Approx. 440g

Approx. 745g

■ DC input Common specifications

LOAD

Rated Load Voltage

Low

24 - 240 V a.c. 50/60 Hz

High

24 - 480 V a.c. 50/60 Hz

Peak Voltage

(Non-repetition)

Low

1,200 V

High

Rated load current

15A

25A

40A

Surge current 60 Hz

(8.3 ms No repetition)

Low

170A

260A

420A

High

170A

250A

370A

Surge current 50 Hz

(10 ms No repetition)

Low

160A

250A

400A

High

170A

230A

350A

Leakage current

Less than 20 mA

Output ON voltage dropping

Less than 1.6 V (R.M.S)

INPUT

Rated Voltage

5 - 24 V d.c.

Operating Voltage Range

(ON Voltage)

4 - 32 V d.c.

return voltage (OFF Voltage)

Less than 3 V

Impedance

Less than 4 kΩ

Current consumption

Constant current method : Less than 14 mA

Response Time

1/2 Cycle + 1 ms max. (“R” type below 1 ms)

Insulating Resistance

500 V d.c., 100 MΩ

(Between the input / output and case)

Dielectric strength

2,500 V a.c. (For 1min at 60 ㎐)

Rated impulse withstand voltage

(Uimp)

2,500 V

Vibration resistance

10 - 55 Hz, Constant current method : 1.5 mm, X·Y·Z each axis direction for 2 hours

Shock resistance

1,000 m/s², X·Y·Z each axis 3 times

Storage Temperature

-30 ~ 90 ℃

Ambient Temperature

-30 ~ 80 ℃ (no condensation)

Ambient Humidity

45 ~ 85 % RH

Pollution level grade

2 Level

bolt tightening torque

Input terminal : 0.05 Nm / Output terminal : 0.25 Nm

Usage

Resistive load

Weight Heating plate removal

(with box)

Approx. 94g

■ AC input

Model

Low

HSR-SLA15LR□□

HSR-SLA25LR□□

HSR-SLA40LR□□

HSR-SLA15LZ□□

HSR-SLA25LZ□□

HSR-SLA40LZ□□

High

HSR-SLA15HR□□

HSR-SLA25HR□□

HSR-SLA40HR□□

HSR-SLA15HZ□□

HSR-SLA25HZ□□

HSR-SLA40HZ□□

LOAD

Rated Load Voltage

Low

24 - 240 V a.c. 50/60 Hz

High

24 - 480 V a.c. 50/60 Hz

Peak Voltage

(Non-repetition)

Low

1,200 V

High

Rated load current

15A

25A

40A

Surge current 60 Hz

(8.3 ms No repetition)

Low

170A

260A

420A

High

170A

250A

370A

Surge current 50 Hz

(10 ms No repetition)

Low

160A

250A

400A

High

170A

230A

350A

Leakage current

Less than 20 mA

Output ON voltage dropping

Less than 1.6 V (R.M.S)

INPUT

Rated Voltage

100 - 240 V a.c. 50/60 Hz

Operating Voltage Range

(ON Voltage)

90 - 264 V a.c. 50/60 Hz

return voltage (OFF Voltage)

Less than 50 V

Impedance

Less than 40 kΩ

Current consumption

Less than 14 mA

Response Time

1/2 Cycle + 1 ms max. (“R” type below 1 ms)

Insulating Resistance

500 V d.c., 100 MΩ

(Between the input / output and case)

Dielectric strength

2,500 V a.c. (For 1min at 60 ㎐)

Rated impulse withstand voltage

(Uimp)

2,500 V

Vibration resistance

10 - 55 Hz, Constant current method : 1.5 mm, X·Y·Z each axis direction for 2 hours

Shock resistance

1,000 m/s², X·Y·Z each axis 3 times

Storage Temperature

-30 ~ 90 ℃

Ambient Temperature

-30 ~ 80 ℃ (no condensation)

Ambient Humidity

45 ~ 85 % RH

Pollution level grade

2 Level

bolt tightening torque

Input terminal : 0.05 Nm / Output terminal : 0.25 Nm

Usage

Resistive load

certification

CE RU ROHS2

Weight Integrated heat sink

(with box)

Approx. 226g

Approx. 266g

Weight Heating plate removal

(with box)

Approx. 94g

▍Suffix code

■ CE, UL certified products

Model

Code

Content

HSR-SL

Slim-type single-phase Solid State Relay

Control input

voltage

D

 

 

 

 

 

4 - 32 V d.c.

A

 

 

 

 

 

90 - 240 V a.c.

Rated load current

15

 

 

 

 

15A

25

 

 

 

 

25A

40

 

 

 

 

40A

Operating load voltage

L

 

 

 

24 - 240 V a.c. (Low voltage)

H

 

 

 

24 - 480 V a.c. (High voltage)

Method of operation

Z

 

 

Zero-cross switching (standard product)

R

 

 

Random switching

Heat sink & Option

S

 

Integrated heat sink (standard product)

T

 

Heat sink + Bimetal mounted

N

 

No heat sink

※ CAUTION 1) When using a separate heat sink, you must use a heat sink that meets the thermal resistance table.

point of contact

1C

1 Point of contact (Unmarked)

2C

2 Point of contact (Unmarked)    ※ CAUTION 2) Only for 15 A

※ CAUTION 2) 2 contact : Only available for 15 A items (HSR-SL□15LZS2C, HSR-SL□15HZS2C)

■ S-MARK certified products

Model

Code

Content

HSR-SL

-S

Slim-type single-phase Solid State Relay

Control input

voltage

D

 

 

 

 

 

4 - 32 V d.c.

Rated load current

15

 

 

 

 

15A

25

 

 

 

 

25A

40

 

 

 

 

40A

Operating load voltage

L

 

 

 

24 - 240 V a.c. (Low voltage)

H

 

 

 

24 - 480 V a.c. (High voltage)

Method of operation

Z

 

 

Zero-cross switching (standard product)

Heat sink & Option

S

 

Integrated heat sink (standard product)

※ CAUTION 2) Please refer to the dimensions of the 25A and 40A heat sink.

T

 

Heat sink + Bimetal mounted

N

 

No heat sink

※ CAUTION 1) When using a separate heat sink, you must use a heat sink that meets the thermal resistance table.

▍Dimension

[Unit : mm]

■ CE, UL certified products

◾ 15A, 25A

Dimension

◾ 40A

Dimension

◾ 2C (2 Point of contact)

Dimension

◾ N (Heating plate removal)

Dimension

■ S-MARK certified products

◾ 15A

Dimension

◾ 25A

Dimension

◾ 40A

Dimension