한영넉스

Panel Meter > LM series : HANYOUNG NUX
LM series LCD Display type Multi panelmeter
- Use a wide viewing angle LCD and white backlight
- Short rear length of 68 mm (LM3) and 81 mm (LM6)
- IP66 Protection Structure (Front of Product)
- RMS and AVG Selection Measurement
- MODBUS Communication Support
- Maximum measurement input specification
(500 V d.c., 500 V a.c., 5A d.c., 5A a.c.)

The order from the left is the order in which the information is displayed at the bottom. If you cancel the check, the information will be excluded, and if you check, it will be printed out.

print_icon

▍Specification

Model

LM3/6-DV

LM3/6-DA

LM3/6-AV

LM3/6-AA

Size

• LM3 : 96(W) x 48(H) x 68(D) mm • LM6 : 72(W) x 36(H) x 81(D) mm

Power

100 - 240 V a.c. 50/60 Hz

Power Consumption

▪LM3-N: 6 VA or less    ▪LM3-3R/3RC: 10 VA or less

▪LM3-3RT: 11 VA or less    ▪LM3-3NC/3PC: 9 VA or less

▪LM3-3NT/3PT: 10 VA or less   ▪LM6-N: 5 VA or less

▪LM6-3R: 7 VA or less     ▪LM6-3N/3P: 5 VA or less

▪LM6-RC: 6 VA or less     ▪LM6-RT: 7 VA or less

Input signal

DC voltage

DC current

AC voltage / frequency

AC current / frequency

Input range

500 V / 100 V

50 V / 10 V

5 V / 1 V

200 mV / 50 mV

5 A / 2 A

500 mA / 200 mA

50 mA / 4 - 20 mA

5 mA / 2 mA

500 V / 250 V

110 V / 50 V

20 V / 10 V

2 V / 1 V

5 A / 2 A

500 mA / 200 mA

50 mA / 20 mA

AC measurement method

AVG / RMS selective measurement

Input sampling cycle

50 ms

Input sampling method

OVER sampling method using continuous approximation A / D converter

Maximum allowable input

F.S. of each input range 110 %

Frequency measurement range

0.2 ~ 9999 Hz (Frequency measurement range depends on the decimal point position)

Display

▪ Negative-LCD ▪ 4 digit 2 rows ▪ PV (White) ▪ SV (Green)

Character size

▪LM3 : 17.6 x 10.6 mm ▪LM6 : 7.0 x 11.5 mm

Maximum display

-9999 ~ 9999

Display degree

▪[ 23 ℃ ± 5 ℃ ] - F.S. ± 0.1 % rdg ± 2 digit

▪[ 23 ℃ ± 5 ℃, 5 A ] - F.S. ± 0.3 % rdg ± 3 digit

▪[ 50 ℃ ~ -10 ℃ ] - F.S. ± 0.5 % rdg ±3 digit

▪[ 23 ℃ ± 5 ℃ ] - F.S. ± 0.3 % rdg ±3 digit

▪[ 23 ℃ ± 5 ℃, frequency ] - F.S. ± 0.1 % rdg ± 2 digit

▪[ 50 ℃ ~ -10 ℃ ] - F.S. ± 0.5 % rdg ± 3 digit

Control output

▪ Contact output : 3 stage, SPST (1a), 250 V a.c. 5 A

▪ Solid state output: 3-stage, NPN or PNP open collector, 12 - 24 V d.c. 50mA or less

Relay life time

▪ Electrical (about 100,000 times, 250 V a.c. 5 A)

▪ Mechanical (about 5 million times)

Optional output

▪ Transmission output (4-20 mA) ▪ RS-485 output

External input

▪ HOLD/ZERO Optional input ▪ Non-voltage input ▪ Short circuit impedance: 300 Ω or less

▪ Residual voltage: 1 V or less ▪ Impedance when open: 100 kΩ or more

Communication

▪ Communication protocol : Modbus-RTU ▪ Communication method : RS-485 (2-wire half duplex)

▪ Communication speed : 2400 / 4800 / 9600 / 19200 / 38400 bps

Insulation Resistance

100 ㏁ or more (500 V d.c. Mega standard, between conductive terminal and case)

Withstand voltage

2000 V a.c. 60 Hz 1 minute (between conductive terminal and case)

Noise

± 2 kV(Between operation power terminals, Pulse width = 1 us, Square wave noise by noise simulator)

Vibration resistance

10 - 55 ㎐, Single amplitude 0.5 ㎜, 3 - axis angular, 2 hours

Approval

CE/KC/RU

Protection structure

▪ IP66 (front) ▪ Terminal block protection cover applied

Ambient temperature and humidity

-10 ~ 50 ℃, 35 ~ 85 % R.H.

Storage temperature

-20 ~ 65 ℃

▍Suffix Code

Model

Code

Description

LM

-

-

-

LCD Multi Panelmeter

Appearance

3

 

 

 

 

 

96(W) X 48(H) mm

6

 

 

 

 

 

72(W) X 36(H) mm

Displayable Digit

4

 

 

 

 

4 Digit indication

Input Specification

DV

 

 

 

DC voltage

DA

 

 

 

DC current

AV

 

 

 

AC voltage

AA

 

 

 

AC current

Output specifications

N

 

 

Non only (Indication option output)

R

 

 

1-stage contact output *LM6 only (For LM6-RC/RT, 1-stage contact output fixed.)

3R

 

 

3-stage contact output

3N

 

 

3-stage NPN open collector output

3P

 

 

3-stage PNP open collector output

Optional output

-

 

Non option output

C

 

RS-485 output (MODBUS-RTU)

T

 

Transmission output (4 - 20 mA d.c.)

Power supply voltage

A

100 – 240 V a.c. 50/60 Hz

▍Dimension & Panel cutout

[Unit : ㎜]

■ Dimension

Dimension

Classification

Type

LM3

LM6

Product dimensions

(Including protective cover.)

W

96.0

72.0

H

48.0

36.0

D

55

68

D1

3.5

3.5

D2

16.1

16.1

L

74.6

87.6

W2

91.0

66.0

H2

44.8

30.5

■ Panel cutout

Panel cutout

Classification

Type

LM3

LM6

Panel cutout

W1

91.5

66.5

H1

45.5

32.0

A

121.5

96.5

B

70.5

57.0